Portable Syngas Analyzer
Introduction
The Portable IR-GAS-600 adopts the imported gas sensor measurement using electrochemical sensor of oxygen, hydrogen measurement using TCD thermal conductivity sensor, methane and carbon dioxide, carbon monoxide, measured using non dispersive infrared gas sensor NDIR principle (selected according to user needs). This instrument cross interference correction based on each component of single measurement, which has high accuracy, short response time, low drift and characteristics simple operation.
Applications
The Syngas analyzer is able to monitor heat treat furnace atmospheres, blast furnace top gas, and some process gasses. They are right for coke ovens, steel manufacturing facilities, synthetic gas production, incinerators and coal plants, coal plants, Biomass gasification, and much more.
Specifications
Measurement
CO, CO2, CH4, CnHm, O2, H2 ,BTU index (gas calorific value)
Calculation
High Heating Value or Low Heating Value in MJ/m3 or kcal/m3
Technology
CO, CO2, CH4, CnHm : proprietary dual beam NDIR detectors
O2 : industrial electrochemical cell
H2 : proprietary thermal conductivity detector
Ranges
CO: 0-100%, CO2: 0-50%, CH4 : 0-10%, CnHm : 0-10%, O2: 0-25%, H2: 0-50%
Other ranges customizable on request without price increase
Resolution
0,01%
Accuracy
≤ ± 1% FS
Statability
≤ 1%FS/7d(zero drift),≤ 1%FS/7d(span drift),
Warm-up
45min
Gas conditions at analyzer inlet
Flow:0.3L-1.0/min, internal gas sampling pump, external flow meter with needle valve
Pressure:0.1Mpa≤ inlet pressure≤ 0.2Mpa
Quality: No dust, moisture, tar (external safety filter and optional gas washing unit)
Operating conditions
Tamb : -5°C -50°C / Pamb : 86 to 108 kPa / RH : 0-90% non condensing
Response time (T90)
≤ 10 sec
Communication interface
USB Port
Power supply
External 220 VAC-50Hz
Internal with battery and charger; Autonomy of > 4h with pump in operation
Battery
12.6V Li-battery,Capacity:10AH
Standby time:
about 12 hours
Dimensions and weight
Gas analyser :270 (L) x 215(W) x 316 (H) mm / ± 2.5kgs
Type of sampling tube
outer Φ6 , inner Φ4