Welcome: Enviro Solutions Technology Co.,ltd
Home      Products     TDLAS Gas Analyser     Laser Gas Analysis System       HCL Laser Gas Analysis System
  • HCL Laser Gas Analysis System

HCL Laser Gas Analysis System

Introduction

eLAS-200 wall-mounted laser gas analysis system using high temperature with heat extraction technology, continuous online monitoring of the system including sampling and transmission unit, pre conditioning and control unit, analysis unit mainly used in many areas of industrial gas emissions monitoring and process control, for example: coal-fired power plant, waste incineration power plant, chemical plant and so on .




Applications

process control/explosion pre-warning monitoring
environmental flue gas emission monitoring
boiler combustion control
air separation and gas production
aerospace, electric power, electronics, biological technology and scientific research institutions, etc


Specifications

Measured gas

HCL/HF

Method

Tunable Diode Laser Spectrometry (TDLS)

Range

HCL/HF: 0-50ppm,0-100ppm,0-500ppm( Customized)

Accuracy

± 1% full scale reading depending on integration stability

(temperature & pressure)

Precision

1ppm

Displayed resolution

0.1ppm

Response time

Less than 15S (at gas flow rate of 3 L/min)

Sampling Gas Temperature

≥180℃

Analog Output

4`20mA DC, Insulating output, maximum load is 900 ohm,

Digital Output

RS232/485

Power Supply

90-240VAC / 50/60Hz 120W

Warm up time

30 minutes

Interface

RS485

Ambient Temperature

Temp:-10-50℃

Humidity:0-90%RH

Dimension

758(L)*500(W)*255(H)mm
580(L)*510(W)*220(H)mm

Weight : 60kgs



INQUIRY