Extractive NH3 Laser Gas Analyzer eLAS-100

Item No.: eLAS-100 NH3
Based on tunable diode laser absorption spectroscopy (TDLAS) technology principle, Online Extractive NH3 Laser Gas Analyzer eLAS-100 scans and analyzes NH3 absorption lines of 1512 nm, and then the concentration of NH3 can be obtained. It adopts extractiv
INQUIRY
Description

Based on tunable diode laser absorption spectroscopy (TDLAS) technology principle, Online Extractive NH3 Laser Gas Analyzer eLAS-100 scans and analyzes NH3 absorption lines of 1512 nm, and then the concentration of NH3 can be obtained. It adopts extractive and In-situ measurement method, getting an rapid and accurate measurement of injecting ammonia or escape ammonia detection in the applications of SCR/SNCR denitration process control.

Features

  • Reliable heated optical path with maximum 3 meters

  • Resolution of 0.1ppm

  • Single spectra scan, no interference from dust, tar and background gases

  • Maintenance-free design

Applications

  • SCR/SNCR denitration process control

  • Engine emissions control

  • Atmosphere monitoring

  • Chemical process control

Specifications

Specifications

Gas

Range

Resolution

Repeatability

Linearity

Response time

Drift

NH3

0-10ppm50ppm

0.1%

≤1%FS

≤1%FS

≤1S

≤±1%FS

Warm up

15min

Digital output

RS232/485

Analog  output

4-20mA  with max load 900Ω

Power  supply

AC100-240V/47-63Hz

120w

Relay output

Load capacity: AC/DC 4V/1A; Concentration  limitation alarm, abnormal transmittance alarm, abnormal laser temperature  alarm

Optical  path

1-3

Flue  gas temperature

≥180℃ no condense

Flue  gas pressure

Atmosphere  pressure±10kPa

Sample  gas flow

≤6L/min

Ambient  temperature

-10~55

Ambient  pressure

70kPa-120kPa

Dimension

I435X450X136mm  rack type 3U case

Weight

12kg

* Measurement range can be customized

* H2O measurement is optional available

* In-situ type gas analyzer needs onsite application conditions.